1200W120VGX95 12/CS 1/SKU Osram 55035
Cross Reference:
- 71/2529 1200w 120v GX9.5 Philips 221523
- 1200W GX9.5 120V 1CT
- HWMV 1200W/115V Osram 54796
- HWMV 1200 Ushio
- 1200W/GX9.5/120V/1CT
- 71-2529
- 71/2526
- 71.2529.0120
1200W120VGX95 12/CS Osram 55035 Info
Technical Data
General product information
Product Number 55035
Product Name 1200W120VGX95 12/CS 1/SKU
Ordering Abbreviation 1200W 120V GX9.5
Brand Name OSRAM
General Description
Tungsten Halogen, 1200 watt, 120 volt, GX9.5 base, equivalent to the 71-2529, used in the VL5 series
Application VL5 & VL500 Moving Lights
Electrical data
Nominal Wattage 1200 W
Nominal Voltage 120 V
Type of Current AC
Light technical data
Luminous Flux 34200 lm
Light Center Length – LCL (in) 2.165 in
Light Center Length – LCL (mm) 55 mm
Color Temperature 3200 K
Color Rendering Index 100
Average Rated Life 150 h
Physical attributes
Bulb Shape T8
Maximum Overall Length (in) 4.331 in
Maximum Overall Length (mm) 110 mm
Diameter d (in) 0.984 in
Diameter d (mm) 25.00 mm
Filament C-13D
Filament Dimensions Length (in) 0.4650 in
Filament Dimensions Length (mm) 11.8 mm
Filament Dimensions Width (in) 0.59 in
Filament Dimensions Width (mm) 15 mm
Additional product data
Operating Position Any
Maximum Base Temperature (ºC) 350 C
Cooling Required – Item Weight 2.2 ounces
Product Dimensions 2.2 x 2 x 4.8 inches
Quantity Per Case: 1
Fixtures used in:
- Vari-Lite VL500D Wash Standard Color
- Vari-Lite VL5 71.2529.0120 *
- Vari-Lite VL500 Wash *
- Vari-Lite VL550 Wash
- Vari-Lite 500TM Wash Luminaires
- Vari-Lite VL500TM Wash
- Vari-Lite VL500DTM Wash
Product benefits
- Very high luminous efficacy of up to 100 lm/W
Areas of application
- Film and television recording in daylight conditions, in the studio or outdoors
- Film and TV production (high-wattage lamps)
- Stage (lighting for dramatic effect)
- Entertainment
Product features
- Color temperature: approx. 6,000 K (Daylight)
- Dimmable
- Hot restart capability
- High color rendering index: Ra > 90
Safety advice
Because of their high luminance, UV radiation (does not apply to HMI UVS) and high internal pressure during operation, HMI lamps may only be operated in enclosed lamp casings specially constructed for the purpose. Appropriate filters must ensure that UV radiation of standard HMI lamps is reduced to an acceptable level. Mercury is released if the lamp breaks. Special safety precautions must be taken. Information on safety and handling is available on request or can be found in the leaflet included with the lamp or in the operating instructions.